EN
Thermal Conductivity Coefficient Test
2013.05.15

The Cryogenic Vessels Quality Supervision and Inspection Center (Guangzhou)/ information card for test item

 

Test Item

Equivalent Thermal Conductivity Coefficient of Material

 

Instrument Used

 

Equivalent Thermal Conductivity Coefficient Test System (self-development)

 

Main Purpose

 

Measure equivalent Thermal Conductivity Coefficient of material under vacuum conditions.

 

Technical Specifications

 

Ultimate vacuum of the vacuum unit: 1×10-5Pa flow meter

 

Measuring range: 0-1500SLPMaccuracy0.2%

 

Attachment

 

Used to measure the equivalent conductivity coefficient of fiber heat insulation material, power (foam) insulation material, fiber and power mixed material under vacuum conditions.

Zip Code: 528251
Tel: 0757-66860226
Fax: 0757-66860225